Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Data sent/received with control modules connected to LIN | No change or Checksum error |
Time Needed for Diagnosis: 1260 ms
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.