LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Subaru >> 2017 >> Outback 2.5i >> Repair and Diagnosis >> Electrical >> Charging Systems >> Starting System & Charging System (H4DO) >> Generator >> Inspection >> Diode
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Starting System & Charging System (H4DO): Generator: Inspection: Diode

CAUTION: There is the possibility of damaging the diodes if a mega-tester (used to measure high voltages) or a similar measuring instrument is used. Never use a mega tester or equivalent for this test.
  1. Check for continuity between the diode lead and terminal E or B. If continuity is not as shown in the table, replace the rectifier.
    • At analog type tester
    Tester lead Continuity
    -lead +lead
    E P1, P2, P3, P4, P5, P6 Yes
    B None
    P1, P2, P3, P4, P5, P6 E None
    B Yes
    • At digital type tester
    Tester lead Continuity
    -lead +lead
    E P1, P2, P3, P4, P5, P6 None
    B Yes
    P1, P2, P3, P4, P5, P6 E Yes
    B None
Fig 1: Checking Continuity Between Diode Lead And Terminal E Or B
G07665194Courtesy of SUBARU OF AMERICA, INC.