Diagnostic Method
Compare the diagnostic value with the threshold value, and if a condition meeting the malfunction criteria listed below continues for 10 s x 3 time(s) or more, judge that there is a fault in the fuel system.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Offset amount of main feedback compensation | ≥ Value from Map |
Map
| Amount of air g/s (oz/s) | 0 (0) | 3.2 (0.11) | 6.4 (0.23) | 9.6 (0.34) | 12.8 (0.45) | 16 (0.56) | 19.2 (0.68) |
| Threshold Value | 1.33 | 1.33 | 1.33 | 1.33 | 1.33 | 1.33 | 1.33 |
Time needed for diagnosis: 10 s x 3 time(s)
Malfunction indicator light illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.