DTC P0452: EVAP System (CPC) Pressure Sensor/Switch Circuit Low: Notes
DTC detecting condition:
Immediately at fault recognition
Wiring diagram:
Engine Electrical System Ref. to WIRING SYSTEM (CROSSTREK MODEL)>Engine Electrical System>WIRING DIAGRAM .
- CHECK DATA MONITOR
.
- Turn the ignition switch to ON.
- Using the Subaru Select Monitor or a general scan tool, read the value of [Barometric Pressure].
Data Monitor
NOTE:- SUBARU SELECT MONITOR For detailed operation procedures, refer to "Data Monitor". Ref. to ENGINE (DIAGNOSTICS) (H4DO)>DATA MONITOR .
- General scan tool For detailed operation procedures, refer to the general scan tool operation manual.
Is the value in [Barometric Pressure] 34 kPa (255 mmHg, 10 inHg) or less?
Yes: Go to 2.
No: Even if DTC is detected, the circuit has returned to a normal condition at this time.
Reproduce the failure, and then perform the diagnosis again.
NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause. - CHECK POWER SUPPLY OF LEAK CHECK VALVE ASSEMBLY (SHORT TO GROUND)
.
- Turn the ignition switch to OFF.
- Disconnect the connector from the leak check valve assembly.
- Turn the ignition switch to ON.
- Measure the voltage between the leak check valve assembly connector and chassis ground.
Connector & terminal
(R400) No. 6 (+) - Chassis ground (-):
Is the voltage 4.5 V or more?
Yes: Go to 3.
No: Repair the harness and connector.
NOTE: In this case, repair the following item:- Open circuit in harness between ECM connector and the leak check valve assembly connector
- Poor contact of ECM connector
- Poor contact of coupling connector
- CHECK HARNESS BETWEEN ECM AND LEAK CHECK VALVE ASSEMBLY (SHORT TO GROUND)
.
- Turn the ignition switch to OFF.
- Disconnect the connector from ECM.
- Measure the resistance between ECM connector and chassis ground.
Connector & terminal
(B134) No. 61 - Chassis ground:
Is the resistance 1 MΩ or more?
Yes: Go to 4.
No: Repair the short circuit to ground in harness between ECM connector and leak check valve assembly connector.
- CHECK FOR POOR CONTACT
.
Check for poor contact of leak check valve assembly connector.
Is there poor contact in the leak check valve assembly connector?
Yes: Repair the poor contact in the leak check valve assembly connector.
No: Replace the leak check valve assembly. Ref. to EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES) (H4DO)>LEAK CHECK VALVE ASSEMBLY .