VDC Control Module Parameter Writing
- Perform writing of parameter.
- Connect the Subaru Select Monitor.NOTE: For detailed operation procedures, refer to "Application help".
- Turn the ignition switch to ON.
- On <<Start>> display, select <<Diagnosis>>.
- On <<Vehicle selection>> display, input the target vehicle information and select <<Confirmed>>.
- On <<Main Menu>> display, select <<Each System>>.
- On <<Select System>> display, select <<Brake Control System>> and select <<Enter>>.
- On <<Select Function>> display, select <<Work Support>>.
- On <<Work Support>> display, select <<Writing of parameter: SSM to ECM>>.
- Connect the Subaru Select Monitor.
- Open the file saved in the <<Reading of parameter: ECM to SSM>> procedure.
- When the confirmation screen indicating the vehicle information appears, check that the correct applied model and grade are displayed and click the <<OK>> button.