Execution Condition
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Main feedback | In operation |
| Rear oxygen sensor voltage when fuel cut ends | ≥0.15V |
| ((Fuel system status | = Fuel cut |
| for time) | ≥3000ms |
| followed by fuel system status) | Fuel cut |
| Rear oxygen sensor estimated element temperature when fuel cut ends | ≥500°C (932°F) |
| Amount of intake air | ≥25g/s (0.88oz/s) |