Diagnostic Method
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Receives internal abnormality | ON |
| or | |
| Receives temperature sensor error | ON |
| or | |
| Receives voltage sensor error | ON |
| or | |
| Receives current sensor error | ON |
Time needed for diagnosis: Less than 1 second