DTC P2017: TGV Position Sensor/Switch Circuit High Bank 1: Notes
DTC detecting condition:
Immediately at fault recognition
Trouble symptom:
- Improper idling
- Engine stalls.
- Poor driving performance
Wiring diagram:
Engine Electrical System Ref. to WIRING SYSTEM>Engine Electrical System>WIRING DIAGRAM .
- CHECK CURRENT DATA
.
- Start the engine.
- Read the value of «TGV Position Sensor R» using the Subaru Select Monitor.NOTE: For detailed operation procedures, refer to "Read Current Data For Engine". Ref. to ENGINE (DIAGNOSTICS) (STI)>Subaru Select Monitor .
Is the value of «TGV Position Sensor R» 5 V or more?
Yes: Go to 2.
NO: Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause. - CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ASSEMBLY RH CONNECTOR
.
- Turn the ignition switch to OFF.
- Disconnect the connector from tumble generator valve assembly RH.
- Start the engine.
- Read the value of «TGV Position Sensor R» using the Subaru Select Monitor.NOTE: For detailed operation procedures, refer to "Read Current Data For Engine". Ref. to ENGINE (DIAGNOSTICS) (STI)>Subaru Select Monitor .
Is the value of «TGV Position Sensor R» 5 V or more?
Yes: Repair the short circuit to power in harness between ECM connector and tumble generator valve assembly RH connector.
No: GO to 3.
- CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ASSEMBLY RH CONNECTOR
.
- Turn the ignition switch to OFF.
- Measure the resistance of harness between tumble generator valve assembly RH connector and engine ground.
Connector & terminal
(E55) No. 2 - Engine ground:
Is the resistance less than 5 Ω?
Yes: Go to 4.
NO: Repair the harness and connector.
NOTE: In this case, repair the following item:- Open circuit in harness between ECM connector and tumble generator valve assembly RH connector
- Poor contact of ECM connector
- Poor contact of coupling connector
- CHECK FOR POOR CONTACT
.
Check for poor contact of tumble generator valve assembly RH connector.
Is there poor contact of the tumble generator valve assembly RH connector?
Yes: Repair the poor contact of tumble generator valve assembly RH connector.
No: Replace the tumble generator valve assembly RH. Ref. to FUEL INJECTION (FUEL SYSTEMS) (STI)>Tumble Generator Valve Assembly .