Diagnostic Method
Judge as NG when one of the following conditions is established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| (1) Absolute value monitoring | |
| A/D voltages for monitoring or A/D voltages for monitoring |
> 2.7 V < 2.5 V |
| (2) A/D/changes monitoring | |
| |(Buffer voltage of AD changes - base voltage of A/D changes)| | > 0.029296875V |
| (3) A/D voltages for monitoring | Did not change |
| (4) |(Throttle position sensor (Main) - (amplified throttle position sensor (Main))/4)| | ≥ 3° |
| (5) (Amplified throttle position sensor (Main))/4 | ≥ 23.8235° |
Time needed for diagnosis:
(1): 200ms
(2): 200ms
(3): 200ms
(4): 24ms
(5): 24ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.