Final ignition timing diagnosis
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Final ignition timing - ignition timing during CSERS* *: Ignition timing during CSERS (Cold Start Emission Reduction Strategy) = Base ignition timing - retard amount |
> 6°CA |
time needed for diagnosis: 6000ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.