DTC P2008: TGV Control Circuit/Open Bank 1: Notes
DTC detecting condition:
Immediately at fault recognition
Wiring diagram:
Engine Electrical System Ref. to WIRING SYSTEM>Engine Electrical System>WIRING DIAGRAM .
- CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ASSEMBLY RH CONNECTOR
.
- Turn the ignition switch to OFF.
- Disconnect the connector from ECM.
- Disconnect the connector from tumble generator valve assembly RH.
- Measure the resistance of harness between ECM connector and tumble generator valve assembly RH connector.
Connector & terminal
(B134) No. 25 - (E55) No. 5:
(B134) No. 26 - (E55) No. 4:
Is the resistance less than 1 Ω?
Yes: Go to 2.
NO: Repair the harness and connector.
NOTE: In this case, repair the following item:- Open circuit in harness between ECM connector and tumble generator valve assembly RH connector
- Poor contact of coupling connector
- CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ASSEMBLY RH CONNECTOR
.
Measure the resistance between ECM connector and chassis ground.
Connector & terminal
(B134) No. 25 - Chassis ground:
(B134) No. 26 - Chassis ground:
Is the resistance 1 MΩ or more?
Yes: Go to 3.
No: Repair the short circuit to ground in harness between ECM connector and tumble generator valve assembly RH connector.
- CHECK FOR POOR CONTACT
.
Check for poor contact of tumble generator valve assembly RH connector.
Is there poor contact of the tumble generator valve assembly RH connector?
Yes: Repair the poor contact of tumble generator valve assembly RH connector.
No: Replace the tumble generator valve assembly RH. Ref. to FUEL INJECTION (FUEL SYSTEMS) (STI)>Tumble Generator Valve Assembly .