Typical Enabling Conditions
TYPICAL ENABLING CONDITIONS (P0512)
| Overlap prohibited DTC | P0500 (Vehicle speed sensor) |
| Battery Voltage | 8V or more |
| Engine Speed | 500 RPM or more |
TYPICAL ENABLING CONDITIONS (P0616)
| Overlap prohibited DTC | P0500 (Vehicle Speed Sensor (VSS)): Without push start system None: With push start system |
| Battery Voltage | 8V or more |
| Engine Speed | Increased from 0 r/min to 500 r/min or more |
| Vehicle speed | Less than 1km/h {0.6 MPH} |
| ST relay | ON |
TYPICAL ENABLING CONDITIONS (P0617)
| Overlap prohibited DTC | None |
| Battery Voltage | 8V or more |
| Engine Speed | 500 RPM or more |
| ST relay | OFF |
TYPICAL ENABLING CONDITIONS (P081A)
| Overlap prohibited DTC | None |
| Battery Voltage | 8V or more |
| Vehicle speed | Less than 1km/h {0.6 MPH} |
| Engine Speed | Increased from 0 r/min to 500 r/min or more |
| ST relay | OFF |