Remote Control Mirror Switch: Inspection
- Check the resistance between switch - door mirror terminals.
Preparation tool:
Circuit tester
- Changeover switch RH
Terminal No. Inspection conditions Standard 12 - 1
12 - 18OFF 1 MΩ or more 12 - 18
17 - 1UP Less than 1 Ω 12 - 17
18 - 1DOWN Less than 1 Ω 12 - 16
18 - 1LEFT Less than 1 Ω 12 - 18
16 - 1RIGHT Less than 1 Ω - Changeover switch LH
Terminal No. Inspection conditions Standard 12 - 1
12 - 21OFF 1 MΩ or more 12 - 20
21 - 1DOWN Less than 1 Ω 12 - 21
20 - 1UP Less than 1 Ω 12 - 19
21 - 1LEFT Less than 1 Ω 12 - 21
19 - 1RIGHT Less than 1 Ω - Changeover switch RH
- If the inspection result is not within the standard, replace the switch - door mirror.