Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Minimum stop position or |
< 9.975° or > 20.025° |
| |Throttle opening angle when the ignition switch is ON - Throttle minimum stop position| | < 1.162° |
time needed for diagnosis: 8ms-80ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.