Diagnostic Method
Judge as NG when one of the following conditions is established.
Judgment Value
| Malfunction Criteria | Threshold Value |
|---|---|
| (1) Main throttle opening angle - Main throttle opening angle at monitoring start | ≥2° |
| (2) Monitoring IC motor continuity cut demand | None |
| (3) Monitoring IC register writing value | Reading value |
Time Needed for Diagnosis:
- 24ms
- 2984 ms = (25+ 6) x 0.008 + (4 x25+ 4) x 0.008 + (5 x25+ 9) x 0.008 + (2 x25) x 0.008 + (25+ 2) x 0.008 x 2
- 200ms
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.