Steering Lock Control Module
| Terminal No. | Contents | Measuring condition | Standard |
|---|---|---|---|
| (B424) No. 1 ←→ Chassis ground | Ground | Always *1 | Less than 1 Ω |
| (B424) No. 2 | - | - | - |
| (B424) No. 3 ←→ Chassis ground | Steering lock motor drive power supply | Motor not operating → Motor operating | 9.5 V or more → 1 V or less |
| (B424) No. 4 ←→ Chassis ground | Unlock position output | Lock → Unlock | 9.5 V or more → 1 V or less |
| (B424) No. 5 | LIN communication | ACC ON, IGN ON or power OFF, and open/close the door | Pulse generation |
| (B424) No. 6 ←→ Chassis ground | Ignition power supply | Ignition switch ON *1 | 9.5 V or more |
| (B424) No. 7 ←→ Chassis ground | Battery power supply | Always *1 | 9.5 V or more |
NOTE:
*1: Perform while the steering lock control module connector is disconnected.