Diagnostic Method
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATION - DIAGNOSIS 1
| Malfunction Criteria | Threshold Value |
|---|---|
| Written value to RAM | Not equal to the reading value |
JUDGMENT VALUE SPECIFICATION - DIAGNOSIS 2
| Malfunction Criteria | Threshold Value |
|---|---|
| Check error of error correction code | Detected |
Time needed for diagnosis : 2 times
Malfunction indicator light illumination : Illuminates as soon as a malfunction occurs.