Execution Condition
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Main feedback | In operation |
| (Duration of fuel cut | ≥3000 ms |
| Fuel shut-off function from above) | Not in operation |
| Output voltage value of rear oxygen sensor | ≥0.2V |
| Compensation to rich | Rich |
| Amount of intake air | ≥10g/s (0.35oz/s) |
| Estimated temperature of the rear oxygen sensor element | ≥500°C (932°F) |