Execution Condition
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage | ≥ 10.9 V |
| Sub feedback | In operation |
| Amount of intake air | ≥10g/s (0.35oz/s) |
| Estimated temperature of the rear oxygen sensor element | ≥500°C (932°F) |
| Enable conditions at interrupt control are as follows Continuous time when rear oxygen sensor output voltage is less than 0.55V |
≥15000 ms |
| Air fuel ratio reduced from target air fuel ratio | = Value of Map |
MAP SPECIFICATION
| Output voltage of rear oxygen sensor (V) | 0.00 | 0.15 | 0.20 | 0.40 | 0.60 |
|---|---|---|---|---|---|
| Air fuel ratio reduced from target air fuel ratio (%) | 15 | 15 | 4 | 4 | 4 |