Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Judgment value
JUDGMENT VALUE SPECIFICATIONS
| Malfunction Criteria |
Threshold Value |
| Number of pulses from overcurrent detection circuit |
10 or more |
Time Needed for Diagnosis
: Immediately