Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
Judgment value
JUDGMENT VALUE SPECIFICATIONS
| Malfunction Criteria | Threshold Value |
|---|---|
| Diagnosis 1 Difference between AWD solenoid set current and AWD solenoid actual current |
More than 950 mA |
| Diagnosis 2 AWD solenoid actual current |
More than 3121 mA |
Time needed for diagnosis: 1.2 s