LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Subaru >> 2021 >> Forester Sport >> Repair and Diagnosis (Single Page) >> Body & Frame >> Door Locks >> Power Rear Gate System (Diagnostics) >> Control Module I/O Signal >> Electrical Specification >> Power Rear Gate Control Module
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Power Rear Gate Control Module

G13229289Courtesy of SUBARU OF AMERICA, INC.
Terminal No. Contents Measuring condition Standard
(R422) No. 1 ← → (R422) No. 9 Touch sensor When sensor is ON 2.7 V or less
(R422) No. 2 - - -
(R422) No. 3 ← → (R422) No. 9 Latch switch When rear gate is fully closed 3.7 - 16 V
(R422) No. 4 ← → (R422) No. 9 Courtesy switch When rear gate is fully closed 3.7 - 16 V
(R422) No. 5 ← → (R422) No. 9 Sector switch When rear gate is fully closed 3.7 - 16 V
(R422) No. 6 ← → (R422) No. 9 Power rear gate inner SW When power rear gate inner switch is ON Less than 1 V
(R422) No. 7 - - -
(R422) No. 8 ← → Chassis ground Memory height switch When memory height switch is ON Less than 1 V
(R422) No. 9 Switch GND - -
(R422) No. 10 - - -
(R422) No. 11 ← → (R422) No. 9 Ratchet switch When rear gate is fully closed Less than 1 V
(R422) No. 12 - - -
(R422) No. 13 ← → Chassis ground Power rear gate driver's switch When driver's switch is ON Less than 1 V
(R422) No. 14 ← → Chassis ground LIN communication line - -
(R422) No. 15 ← → Chassis ground Hazard output When hazard is not operating Less than 1 V
(R422) No. 16 ← → Chassis ground Ignition SW When ignition switch is ON 9 - 16 V
(R423) No. 1 ← → Chassis ground Battery power supply (+POWER B) Always 9 - 16 V
(R423) No. 2 ← → Chassis ground Closer (CLOSE) When power rear gate auto closer is in pull-in operation 9 - 16 V
(R423) No. 3 ← → Chassis ground Closer (OPEN) When power rear gate auto closer is performing the release operation 9 - 16 V
(R423) No. 4 ← → Chassis ground GND Always Less than 1 Ω
(R423) No. 5 - - -
(R423) No. 6 ← → Chassis ground Battery power supply (+B) Always 9 - 16 V
(R424) No. 1 - - -
(R424) No. 2 - - -
(R424) No. 3 ← → Chassis ground Motor (CLOSE) When auto-closing is in operation Pulse
(R424) No. 4 ← → Chassis ground Motor (OPEN) When auto-open is in operation Pulse
(R424) No. 5 Buzzer (-) - -
(R424) No. 6 ← → (R424) No. 5 Buzzer (+) When buzzer sounds Pulse
(R424) No. 7 - - -
(R424) No. 8 ← → Chassis ground HALL RETURN - -
(R424) No. 9 ← → (R424) No. 8 HALL2 - -
(R424) No. 10 ← → (R424) No. 8 HALL1 - -
(R424) No. 11 ← → Chassis ground HALL FEED - -
(R424) No. 12 - - -
(R424) No. 13 - - -
(R424) No. 14 - - -