Home >> Subaru >> 2021 >> Legacy Base >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System (2.5L) (Diagnostics) (4 Of 4) >> Diagnostic Procedure With Diagnostic Trouble Code (DTC) >> DTC P24B9: EVAP System Leak Detection Pump Pressure Sensor Circuit Range/Performance >> Notes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

DTC P24B9: EVAP System Leak Detection Pump Pressure Sensor Circuit Range/Performance: Notes

1. - 

DTC detecting condition: 

Detected when two consecutive driving cycles with fault occur.

NOTE: After the faulty parts are repaired or replaced, perform the final check in Basic Diagnostic Procedure. Ref. to ENGINE (DIAGNOSTICS) (H4DO)>BASIC DIAGNOSTIC PROCEDURE>PROCEDURE .
  1. CHECK DTC  .
    1. Turn the ignition switch to ON.
    2. Using the Subaru Select Monitor or a general scan tool, read the DTC of [Engine]. Ref. to COMMON (DIAG)>DIAGNOSTIC TROUBLE CODE (DTC) .

      Is DTC other than P24B9 displayed? (Current malfunction)

      Yes  : Check the appropriate DTC using the "Diagnostic Trouble Code (DTC)". Ref. to ENGINE (DIAGNOSTICS) (H4DO)>DIAGNOSTIC TROUBLE CODE (DTC)>LIST .

      No  : Go to  2 .

  2. CHECK DATA MONITOR  .
    1. Turn the ignition switch to ON (engine OFF).
    2. Using the Subaru Select Monitor, read the values of [Evap System Vapor Pressure] and [Intake Manifold Absolute Pressure] to compare with actual atmospheric pressure.
      NOTE: For detailed operation procedures, refer to "Common (Diagnostics)". Ref. to COMMON (DIAG)>DATA MONITOR .

      Is the difference with the actual atmospheric pressure 2.53 [kPa] (18.98 mmHg, 0.75 inHg, 0.37 psi) or more?

      Yes  : Replace the part that showed larger deviation from the actual atmospheric pressure than the other.

      No  : Even if DTC is detected, the circuit has returned to a normal condition at this time.

      Reproduce the failure, and then perform the diagnosis again.

      NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.