THERMO Control Valve Assembly

Flow rate characteristics Position 1 Radiator port 20.9 kPa (2.1 mAq) @ 100 L (26.4 US gal, 22.0 Imp gal)/min
Position 2 Bottom port 41.6 kPa (4.2 mAq) @ 100 L (26.4 US gal, 22.0 Imp gal)/min
Position 3 (fully closed) - -
Position 4 Bottom port 15.7 kPa (1.6 mAq) @ 30 L (7.9 US gal, 6.6 Imp gal)/min
Heater port 28.5 kPa (2.9 mAq) @ 20 L (5.3 US gal, 4.4 Imp gal)/min
Position 5 Radiator port 9.7 kPa (1.0 mAq) @ 100 L (26.4 US gal, 22.0 Imp gal)/min
Heater port 12.0 kPa (1.2 mAq) @ 20 L (5.3 US gal, 4.4 Imp gal)/min
Responsiveness Fully closed - Fully open sec 2 or less
Sensor output range V 0.539 - 4.141 (mechanical stop position: 4.297)
Rotor operation range deg 174
Fail-safe thermostat Type Temperature, pressure relief
Starting temperature to open °C (°F) 105 - 109 (221 - 228)
Starting pressure to open kPa (mAq) 210 - 290 (21.4 - 29.6)