Execution Condition
EXECUTION CONDITION - DIAGNOSIS 1
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage Barometric pressure Operation time of main feedback Engine speed Amount of intake air |
10.9 V or more 75.06 kPa (563.1 mmHg, 22.2 inHg) or more 5000 ms or more 1000 rpm or more 10 g/s (0.35 oz/s) or more |
EXECUTION CONDITION - DIAGNOSIS 2
| Secondary parameters | Execution condition |
|---|---|
| Battery voltage Barometric pressure Main feedback Engine speed Amount of intake air Difference of the amount of intake air |
10.9 V or more 75.06 kPa (563.1 mmHg, 22.2 inHg) or more In operation 1000 rpm or more 20 g/s (0.7 oz/s) or more and Less than 100 g/s (3.5 oz/s) 0.5 g/s (0.02 oz/s) or more |