Diagnostic Method
Judge as NG when the following conditions are established.
JUDGMENT VALUE - DIAGNOSIS 1
| Malfunction Criteria | Threshold Value |
|---|---|
| Receives pulse discharge malfunction or | ON |
| Receives voltage measurement malfunction | ON |
| or | |
| Receives current measurement malfunction | ON |
JUDGMENT VALUE - DIAGNOSIS 2
| Malfunction Criteria | Threshold Value |
|---|---|
| Battery current | Less than -1000 A or More than 300 A |
JUDGMENT VALUE - DIAGNOSIS 3
| Malfunction Criteria | Threshold Value |
|---|---|
| Battery voltage | Less than 6 V or More than 16.2 V |
JUDGMENT VALUE - DIAGNOSIS 4
| Malfunction Criteria | Threshold Value |
|---|---|
| Battery temperature | More than 105°C (221°F) |
JUDGMENT VALUE - DIAGNOSIS 5
| Malfunction Criteria | Threshold Value |
|---|---|
| Battery SOC | More than 100% |
JUDGMENT VALUE - DIAGNOSIS 6
| Malfunction Criteria | Threshold Value |
|---|---|
| |Battery current (current value) - Battery current (previous value)| | 0.003 A or less |
Time needed for diagnosis:
Diagnosis 1 : Less than 1 s
Diagnosis 2, 3, 4 and 5 : 10 s
Diagnosis 6 : 60 s
Malfunction indicator light illumination: Does not illuminate.