| <Phase 1> Battery voltage |
≥ 10.9 V |
| Barometric pressure |
≥75.1 kPa (563 mmHg, 22.2 inHg) |
| Integrated purge air amount since engine starting |
≥72 g (2.54 oz) |
| Purge control duty ratio = 0% duration time |
≥1000 ms |
| Ambient air temperature |
> 4.4°C (39.9°F) and < 35°C (95°F) |
| Fuel level |
≥9L (2.38US gal, 1.98Imp gal) |
| Cumulative time for establishment of the following conditions |
≥6016 ms |
- Intake air amount per 1 second
|
> Map |
- Commanded solenoid valve for secondary purge
|
Open |
<Phase 2> Establishing time for following conditions |
≥ 20 s |
|
|
≥ 10.9 V |
|
|
≥75.1 kPa (563 mmHg, 22.2 inHg) |
|
|
≥9L (2.38US gal, 1.98Imp gal) |