DTC P0A3B: Generator/Alternator Over Temperature: Notes
- -
DTC detecting condition:
Immediately at fault recognition
Trouble symptom:
Charge warning light illuminates.
NOTE:After the faulty parts are repaired or replaced, perform the final check in Basic Diagnostic Procedure. Ref. to ENGINE (DIAGNOSTICS) (H4DOTC)>Basic Diagnostic Procedure> PROCEDURE .
- CHECK GENERATOR
.
Check the generator vent window. Ref. to STARTING/CHARGING SYSTEMS) (H4DOTC)>Generator>INSPECTION .
Is there clogging with foreign objects?
Yes : Eliminate the foreign objects and leave the generator main body intact approx. 20 minutes to cool down.
No : Go to 2.
- CHECK CHARGE WARNING LIGHT
.
- Turn the ignition switch to OFF and wait for at least 20 minutes.
- Start the engine and check the charge warning light.
Does the charge warning light remain on?
Yes : Replace the generator. Ref. to STARTING/CHARGING SYSTEMS (H4DOTC)>GENERATOR .
No : This is a temporarily overheating of the generator. It is now back to normal state.
Check for clogging with foreign objects in the proximate area such as the generator vent window.