DTC P24BA: EVAP System Leak Detection Pump Pressure Sensor Circuit Low: Notes
1. - DTC detecting condition:
Immediately at fault recognition
Wiring diagram:
Engine Electrical System Ref. to WIRING SYSTEM>ENGINE ELECTRICAL SYSTEM .
Use the check board when measuring the ECM terminal voltage and resistance. Ref. to ENGINE (DIAGNOSTICS) (H4DOTC)>GENERAL DESCRIPTION>PREPARATION TOOL>HOW TO USE CHECK BOARD .
After the faulty parts are repaired or replaced, perform the final check in Basic Diagnostic Procedure. Ref. to ENGINE (DIAGNOSTICS) (H4DOTC)>BASIC DIAGNOSTIC PROCEDURE>PROCEDURE .
- CHECK DATA MONITOR
.
- Turn the ignition switch to ON.
- Using the Subaru Select Monitor, read the value in [Evap System Vapor Pressure].NOTE:
For detailed operation procedures, refer to "Common (Diagnostics)". Ref. to COMMON (DIAG)>DATA MONITOR .
Is the value in [Evap System Vapor Pressure] 34 kPa (255 mmHg, 10 inHg) or less?
Yes : Go to 2.
No : Even if DTC is detected, the circuit has returned to a normal condition at this time.
Reproduce the failure, and then perform the diagnosis again.
NOTE:In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
- CHECK POWER SUPPLY OF LEAK CHECK VALVE ASSEMBLY
.
- Turn the ignition switch to OFF.
- Disconnect the connector from the leak check valve assembly.
- Turn the ignition switch to ON.
- Measure the voltage between the leak check valve assembly connector and chassis ground.
Connector & terminal
(R400) No. 6 (+) - Chassis ground (-):
Is the voltage 4.5 V or more?
Yes : Go to 3.
No : Repair the following item.
- Open circuit in harness between ECM connector and the leak check valve assembly connector
- Poor contact of ECM connector
- Poor contact of coupling connector
- check harness between ECM and leak check valve assembly connector (short to ground)
.
- Turn the ignition switch to OFF.
- Disconnect the connector from ECM.
- Measure the resistance between the ECM connector and engine ground.
Connector & terminal
(E159) No. 31 - Engine ground:
Is the resistance 1 MΩ or more?
Yes : Go to 4.
No : Repair the short circuit to ground in harness between ECM connector and leak check valve assembly connector.
- CHECK FOR POOR CONTACT
.
Check for poor contact of leak check valve assembly connector.
Is there poor contact in the leak check valve assembly connector?
Yes : Repair the poor contact in the leak check valve assembly connector.
No : Replace the leak check valve assembly. Ref. to EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES) (H4DOTC)>LEAK CHECK VALVE ASSEMBLY .