Execution Condition
EXECUTION CONDITION - P04F0
| Secondary parameters | Execution condition |
|---|---|
| <High pressure side pressure system> | |
| Battery voltage | 10.9 V or more |
| Barometric pressure | 75.06 kPa (563.1 mmHg, 22.2 inHg) or more |
| Intake manifold absolute pressure - Barometric pressure | 30.05 kPa (225.4 mmHg, 8.9 inHg) or more |
| Ambient air temperature | More than 4.4°C (39.9°F) |
| Purge control duty ratio | 40% or more |
| Elapsed time after the switching valve in the leak check valve assembly opened | 4 s or more |
EXECUTION CONDITION - P04F1
| Secondary parameters | Execution condition |
|---|---|
| <Low pressure side pressure system> | |
| Battery voltage | 10.9 V or more |
| Barometric pressure | 75.06 kPa (563.1 mmHg, 22.2 inHg) or more |
| Barometric pressure - Intake manifold absolute pressure | 25.05 kPa (187.9 mmHg, 7.4 inHg) or more |
| Estimated ejector generation negative pressure | 1.5 kPa (11.3 mmHg, 0.4 inHg) or less |
| Ambient air temperature | More than 4.4°C (39.9°F) |
| Purge control duty ratio | 40% or more |
| Elapsed time after the switching valve in the leak check valve assembly opened | 4 s or more |