Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Fully closed position learning value | Less than -3 mm (-0.12 in) Or, More than 4.3 mm (0.17 in) |
Time needed for diagnosis: Less than 1 s
Malfunction indicator light illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.