DTC U171F: Lost Lin Communication With Generator: Notes

DTC detecting condition: 

Immediately at fault recognition

Wiring diagram: 

Charging System Ref. to WIRING SYSTEM>CHARGING SYSTEM .

G16446454Courtesy of SUBARU OF AMERICA, INC.
CAUTION: Use the check board when measuring the ECM terminal voltage and resistance. Ref. to ENGINE (DIAGNOSTICS) (H4DOTC)>GENERAL DESCRIPTION>PREPARATION TOOL>HOW TO USE CHECK BOARD .
NOTE: After the faulty parts are repaired or replaced, perform the final check in Basic Diagnostic Procedure. Ref. to ENGINE (DIAGNOSTICS) (H4DOTC)>BASIC DIAGNOSTIC PROCEDURE>PROCEDURE .
  1. CHECK DTC  .
    1. Turn the ignition switch to ON.
    2. Using the Subaru Select Monitor or a general scan tool, read the DTC of [Engine]. Ref. to COMMON (DIAGNOSTICS)>DIAGNOSTIC TROUBLE CODE (DTC) .

    Is DTC U171F displayed? (Current code)

    Yes:  Go to  2.

    No:  Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.

  2. CHECK ECM CONNECTOR  .

    Check the connecting condition of ECM connector.

    Is the ECM connector correctly connected?

    Yes:  Go to  3.

    No:  Connect the ECM connector correctly.

  3. CHECK VOLTAGE OF GENERATOR TERMINAL B  .
    1. Turn the ignition switch to OFF.
    2. Disconnect the ground terminal from battery sensor. Ref. to REPAIR CONTENTS>NOTE>BATTERY .
    3. Measure the voltage of the generator terminal B.

      Connector & terminal 

      Generator terminal B (+) - Engine ground (-):

    Is the voltage battery voltage?

    Yes:  Go to  4.

    No:  Check the generator terminal B harness and fuse.

  4. CHECK HARNESS BETWEEN ECM AND GENERATOR CONNECTOR (OPEN)  .
    1. Disconnect the connector from ECM.
    2. Disconnect the LIN communication connector from the generator.
    3. Measure the resistance of harness between ECM and generator LIN communication connector.

      Connector & terminal 

      (B134) No. 20 - (F26) No. 1:

    Is the resistance less than 1 Ω?

    Yes:  Check the connector for poor contact and check the harness again. If no fault is found, replace the generator. Ref. to STARTING/CHARGING SYSTEMS (H4DOTC)>GENERATOR .

    No:  Repair the following item.

    • Open circuit of harness between ECM connector and generator
    • Poor contact of coupling connector
    • Poor contact of J/C