Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Output voltage | 1.9 V or less |
| Or, | |
| Output voltage | More than 2.3 V |
| Output current | Less than 0.03 mA |
Time needed for diagnosis: 2500 ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.