Home >> Subaru >> 2023 >> Ascent Base >> Repair and Diagnosis (Single Page) >> Engine Performance >> Testing & Diagnosis >> Engine Control System (Diagnostics) (4 Of 4) >> Diagnostic Procedure with Diagnostic Trouble Code (DTC) >> DTC P24B9: EVAP System Leak Detection Pump Pressure Sensor Circuit Range/Performance >> General Description >> Execution Condition
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Execution Condition

Secondary parameters Execution condition
Elapsed time after ignition switch is turned to ON 500 ms or more
and
Less than 60 s
Soaking time 60 s or more
Vacuum pump in the leak check valve assembly Not in operation
Switching valve in the leak check valve assembly Open
Purge control Not in operation