Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value |
|---|---|
| Sensor 1 input voltage | 0.276V or less |
Time needed for diagnosis : 24 ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.