DTC P2012: TGV Control Circuit Low Bank 2: Notes
DTC detecting condition:
Immediately at fault recognition
CAUTION:
Use the check board when measuring the ECM terminal voltage and resistance. Ref. to ENGINE (DIAGNOSTICS) (H4DO)>GENERAL DESCRIPTION>PREPARATION TOOL>HOW TO USE CHECK BOARD
.
NOTE:
After the faulty parts are repaired or replaced, perform the final check in Basic Diagnostic Procedure. Ref. to ENGINE (DIAGNOSTICS) (H4DO)>BASIC DIAGNOSTIC PROCEDURE>PROCEDURE
.
Wiring diagram:
Engine Electrical System Ref. to WIRING SYSTEM>ENGINE ELECTRICAL SYSTEM .
- CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ACTUATOR LH CONNECTOR (SHORT TO POWER SUPPLY)
.
- Turn the ignition switch to OFF.
- Disconnect the connector from ECM.
- Measure the voltage between ECM connector and engine ground.
Connector & terminal
(E158) No. 101 (+) - Engine ground (-):
(E158) No. 110 (+) - Engine ground (-):
Is the voltage 5 V or more?
Yes: Repair the short circuit to power in harness between ECM connector and tumble generator valve actuator LH connector.
No: Replace the tumble generator valve actuator LH. Ref. to FUEL INJECTION (FUEL SYSTEMS) (H4DO)>TUMBLE GENERATOR VALVE ACTUATOR .
NOTE: The tumble generator valve actuator cannot be disassembled.