Diagnostic Method
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.
JUDGMENT VALUE SPECIFICATION
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| Output voltage | Less than 0.211V | P2016 |
| Output voltage | Less than 0.211V | P2021 |
Time needed for diagnosis: 500 ms
Malfunction indicator light illumination: Illuminates as soon as a malfunction occurs.