Execution Condition
SECONDARY PARAMETER AND EXECUTION CONDITION - MONITOR #1 (TIMER DIAGNOSIS)
| Secondary parameters | Execution condition |
|---|---|
| Ignition switch | OFF |
| Battery voltage | 10.9 V or more |
| Elapsed time after starting the engine | More than 19 s and Less than 61439 s |
SECONDARY PARAMETER AND EXECUTION CONDITION - MONITOR #2 (FULL COUNT DIAGNOSIS)
| Secondary parameters | Execution condition |
|---|---|
| Ignition switch | OFF |
| Battery voltage | 10.9 V or more |
| Counter in ECM | 4 s or more |
SECONDARY PARAMETER AND EXECUTION CONDITION - MONITOR #3 (SOAKING TIMER IC SETTING DIAGNOSIS)
| Secondary parameters | Execution condition |
|---|---|
| Ignition switch | OFF |
| Battery voltage | 10.9 V or more |
SECONDARY PARAMETER AND EXECUTION CONDITION - MONITOR #4 (TIMER DIAGNOSIS - DURING SOAKING)
| Secondary parameters | Execution condition |
|---|---|
| Ignition switch | OFF |
| Battery voltage | 10.9 V or more |
SECONDARY PARAMETER AND EXECUTION CONDITION - MONITOR #5 (WAKE-UP DIAGNOSIS)
| Secondary parameters | Execution condition | |
|---|---|---|
| Ignition switch | ON Time in the soaking timer IC |
More than 3600s |