DTC P2016: TGV Position Sensor/Switch Circuit Low Bank 1: Notes
DTC detecting condition:
Immediately at fault recognition
Trouble symptom:
- Improper idling
- Engine stall
- Poor driving performance
Wiring diagram:
Engine Electrical System Ref. to WIRING SYSTEM>ENGINE ELECTRICAL SYSTEM .
- CHECK DATA MONITOR
.
- Start the engine.
- Using the Subaru Select Monitor, read the value in [TGV Position Sensor R].NOTE: For detailed operation procedures, refer to "COMMON (DIAGNOSTICS)". Ref. to COMMON (DIAGNOSTICS)>DATA MONITOR .
Is the value of [TGV Position Sensor R] less than 0.2 V?
Yes: Go to 2.
No: Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause. - CHECK POWER SUPPLY OF TUMBLE GENERATOR VALVE ACTUATOR RH
.
- Turn the ignition switch to OFF.
- Disconnect the connector from tumble generator valve actuator RH.
- Turn the ignition switch to ON.
- Measure the voltage between tumble generator valve actuator RH connector and engine ground.
Connector & terminal
(E55) No. 3 (+) - Engine ground (-):
Is the voltage 4.5 V or more?
Yes: Go to 3.
No: Repair the following item.
- Open circuit in harness between ECM connector and tumble generator valve actuator RH connector
- Poor contact of ECM connector
- CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ACTUATOR RH CONNECTOR (OPEN)
.
- Turn the ignition switch to OFF.
- Disconnect the connector from ECM.
- Measure the resistance of harness between ECM connector and tumble generator valve actuator RH connector.
Connector & terminal
(E158) No. 28 - (E55) No. 1:
Is the resistance less than 1 Ω?
Yes: Go to 4.
No: Repair the open circuit in harness between ECM connector and tumble generator valve actuator RH connector.
- CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ACTUATOR RH CONNECTOR (SHORT TO GROUND)
.
Measure the resistance between the ECM connector and engine ground.
Connector & terminal
(E158) No. 28 - Engine ground:
Is the resistance 1 MΩ or more?
Yes: Go to 5.
No: Repair the short circuit to ground in harness between ECM connector and tumble generator valve actuator RH connector.
- CHECK FOR POOR CONTACT
.
Check for poor contact of ECM and tumble generator valve actuator RH connector.
Is there poor contact of ECM or the tumble generator valve actuator RH connector?
Yes: Repair the poor contact of ECM or tumble generator valve actuator RH connector.
No: Replace the tumble generator valve actuator RH. Ref. to FUEL INJECTION (FUEL SYSTEMS) (H4DO)>TUMBLE GENERATOR VALVE ACTUATOR .
NOTE: The tumble generator valve actuator cannot be disassembled.