October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Negative rectifier
- Using an ohmmeter, connect one tester probe to each negative terminal (1) and the other to each rectifier terminal (2).
- Reverse the polarity of the tester probes and repeat Step 1.
- Check that one shows continuity and the other shows no continuity. If there is continuity, replace the rectifier.
Courtesy of SUZUKI OF AMERICA CORP.