A/C Compressor Relay Control System Check: Troubleshooting
A/C COMPRESSOR RELAY CONTROL - TROUBLESHOOTING CHART
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | A/C compressor control circuit check
Is voltage 10 - 14 V? |
Go to Step 3. | Go to Step 2. |
| 2 | A/C compressor control circuit check
Is check result as specified? |
"YEL/GRN" wire or "PNK" wire is open circuit. | Faulty A/C compressor relay. |
| 3 | A/C compressor control signal check
Is voltage 0 - 1 V? |
Go to Step 4. | Go to Step 5. |
| 4 | A/C compressor control circuit check
Is check result as specified? |
"RED/BLK" wire or "WHT/RED" wire is open circuit. If wire circuits are OK, check A/C compressor referring to MAGNET CLUTCH OPERATING CHECK : Manual Type. |
Faulty A/C compressor relay. |
| 5 | A/C switch signal check
Is voltage 0 - 1 V? |
Poor performance of ECT sensor or its circuit. If they are OK, substitute a known-good ECM and recheck. | Faulty "GRN/BLK" wire, A/C evaporator temperature is below 2.5 °C, 36.5 °F, faulty refrigerant pressure switch or faulty A/C system referring to HVAC CONTROL MODULE AND ITS CIRCUITS INSPECTION : Manual Type or HVAC CONTROL MODULE AND ITS CIRCUITS INSPECTION : Automatic Type. |