LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2007 >> Grand Vitara 2WD V6-2.7L >> Repair and Diagnosis >> Accessories and Optional Equipment >> Antitheft and Alarm Systems >> Keyless Entry >> Keyless Starting System >> Testing and Inspection >> Component Tests and General Diagnostics >> Inspection of Keyless Start Control Module and Its Circuits
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Inspection of Keyless Start Control Module and Its Circuits

Inspection of Keyless Start Control Module and Its Circuits

Keyless start control module and its circuits can be checked at keyless start control module wiring couplers by measuring voltage and resistance.

CAUTION: Keyless start control module cannot be checked by itself. It is strictly prohibited to connect voltmeter or ohmmeter to keyless start control module with coupler disconnected from it.

Voltage Check





























































1. Disconnect negative cable (-) at battery.
2. Remove keyless start control module from vehicle body referring to Keyless Start Control Module Removal and Installation.
3. Connect connector to keyless start control module.
4. Check voltage at each terminal number of couplers connected.

NOTE:
- As each terminal voltage is affected by the battery voltage, confirm that it is 11 V or more when ignition switch is ON.
- Voltage with asterisk (*) cannot be measured by voltmeter because it is pulse signal.