Home >> Suzuki >> 2008 >> Reno Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 253 (Engine Control System - Introduction) >> General Description >> OBD System Description - Comprehensive Component (Engine Input) Monitor >> Crankshaft Sensor Diagnosis >> Time Length And Frequency
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Time Length And Frequency

WARNING: This page is about a different car, the 2006 Suzuki Verona. However, it is still accessible from the selected car via links, so may be relevant.

Once per crankshaft revolution

Sampling rate > 7,000 Hz



Signal Implausible/Signal Missing:

Continuous camshaft signal edge counter

And

0 to 1 transition of engine stop

Loss of Synchronization:

Once per crankshaft revolution, after detection of the reference gap, except in the first revolution after

synchronization.

Implausible Tooth Period:

If Flag for crankshaft acquisition synchronized is set: every reference gap.

If Flag for crankshaft acquisition not set: synchronized when Invalid crankshaft tooth period is set.