LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2008 >> Reno Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 253 (Engine Control System - Introduction) >> General Description >> OBD System Description - Comprehensive Component Monitor (Engine Output) >> Control Module Read Only Memory (ROM) Diagnosis >> Malfunction Criteria And Threshold Value(S)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Malfunction Criteria And Threshold Value(S)

WARNING: This page is about a different car, the 2006 Suzuki Verona. However, it is still accessible from the selected car via links, so may be relevant.

General Monitoring Error:

Conditions are fulfilled.

Logical variable for ratio error between Engine Speed and Engine Speed Substitute Monitoring level = 1

Or

Fault currently present in torque generation = true

Or

Monitored minimum torque at clutch = true

Or

Monitored maximum torque at clutch = true

Or

Logical variable for different PVS diagnosis between L1 and L2 = true

Or

Logical variable for different TPS diagnosis between L1 and L2 = true

Or

Logical variable for error in mass air flow signal = true

Error on ROM:

Error in selftest/Predrive check error:

Level 2 Error:

N_LIM Monitoring Error:

Torque Monitoring:

When a fault is detected by the Processor Monitoring (see "fault reaction of processor monitoring"), a reset is done or a transition to DISABLE is preformed. The complete error information is available on the main controller after the first communication past the reset or after the first DISABLE communication (cf. activation conditions of the module).