Malfunction Criteria And Threshold Value(S)
WARNING: This page is about a different car, the 2006 Suzuki Verona. However, it is still accessible from the selected car via links, so may be relevant.
Position Controller Error:
No Error EGR position control
Integral duty cycle for EGR valve control >= 46.609%
=> Decrease the counter to indicate integral term is blocked in low or high limits about 1
Until counter reached 0
=> Error detected
Adaptation outside range:
(Potentiometer low limit learnt > 1.758 V or Potentiometer low limit learnt < 0.161 V)
Timer for the adaptation of the lower mechanical valve stop >= 2 s
=> Error detected