Malfunction Criteria And Threshold Value(S)
Preliminary diagnosis condition are fulfilled
=> The fuel consumption is integrated.
Integrated value of fuel consumption > 3.17006 gallon (12 L)
=> Counter for RBM < 5
=> Counter for RBM increased by 1
Integrated value of fuel consumption offset = Integrated value of fuel consumption + Integrated value of fuel consumption offset
Fuel tank level gradient diagnosis condition to start symptom detection = true
Fuel tank level initialization value for compare - fuel tank volume in liters < 0.528344 gallon (2 L)
Or
Fuel tank level initialization value for compare - fuel tank volume in liters > 5.81179 gallon (22 L)
=> Symptom is active
Fuel tank level initialization value for compare = fuel tank volume in liters
Number of gradient error detections < 5
=> Number of gradient error detections increased by 1
Number of gradient error detections ≥ 5
Failure is set inside ERRM.