October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Generator Inspection: Stator
- Using ohmmeter (1), check continuity between all pairs of leads (2). If there is no continuity between any lead pairs, replace stator.
Courtesy of SUZUKI OF AMERICA CORP.
- Using ohmmeter (1), check that there is no continuity between any of coil leads (2) and stator core (3). If there is continuity, replace stator.
Courtesy of SUZUKI OF AMERICA CORP.