Fail-Safe Mode Table
FAIL-SAFE MODE CHART
| No. | Item | Act condition | Release condition |
|---|---|---|---|
| 1 | Pulse sensor error (one sensor) | After an error is detected from a sensor, no change of pulse from the sensor is detected while specified number of pulses are received from the other sensor. | When specified amount of "up" pulse is detected and motor is stopped at the fully closed position. |
| 2 | Pulse sensor direction error | More than specified number of pulses indicating opposite direction to detected motor rotating direction are successively. | |
| 3 | Pulse sensor stop error (both sensors) | No pulse is detected from both pulse sensors for more than specified time during closing operation. | |
| 4 | Memory error of full close position | When window is rising, ECU receives "up" pulses exceeding the specified amount from sensor. | |
| 5 | Initializing failure | Door glass position cannot be detected correctly when resetting ECU. | When initialization is conducted successfully. |
| 6 | LIN communication failure | LIN communication is interrupted. | When LIN communication is restored. |