October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Cold Start Injector Time Switch Specifications
COLD START INJECTOR TIME SWITCH SPECIFICATIONS
| Application |
Ohms |
Condition |
| Camry |
| 3S-FE |
| 20-40 |
Below 86°F (30°C) |
| 40-60 |
Above 104°F (40°C) |
| 20-80 |
"STA" To Ground |
| 2VZ-FE |
| 25-45 |
Below 59°F (15°C) |
| 65-85 |
Above 86°F (30°C) |
| 25-85 |
"STA" To Ground |
| Celica |
| 3S-GE & 3S-GTE |
| 30-50 |
Below 50°F (10°C) |
| 70-90 |
Above 77°F (25°C) |
| 30-90 |
"STA" To Ground |
| 3S-FE |
| 20-40 |
Below 86°F (30°C) |
| 40-60 |
Above 104°F (40°C) |
| 20-80 |
"STA" To Ground |
| Corolla |
| 20-40 |
Below 86°F (30°C) |
| 40-60 |
Above 104°F (40°C) |
| 20-80 |
"STA" To Ground |
| Cressida |
| 25-45 |
Below 59°F (15°C) |
| 65-85 |
Above 86°F (30°C) |
| 25-85 |
"STA" To Ground |
| Land Cruiser |
| 30-50 |
Below 59°F (15°C) |
| 70-90 |
Above 86°F (30°C) |
| 30-90 |
"STA" To Ground |
| MR2 (1989 Only) |
| 20-40 |
Below 86°F (30°C) |
| 40-60 |
Above 104°F (40°C) |
| 20-80 |
"STA" To Ground |
| Pickup/4Runner |
| 22R-E |
| 30-50 |
Below 50°F (10°C) |
| 70-90 |
Above 77°F (25°C) |
| 30-90 |
"STA" To Ground |
| 3VZ-E |
| 30-50 |
Below 50°F (10°C) |
| 70-90 |
Above 77°F (25°C) |
| 30-90 |
"STA" To Ground |
| Supra |
| 25-45 |
Below 59°F (15°C) |
| 65-85 |
Above 86°F (30°C) |
| 25-85 |
"STA" To Ground |
| Van (1989 Only) |
| 20-50 |
Below 59°F (15°C) |
| 60-85 |
Above 86°F (30°C) |
| 25-85 |
"STA" To Ground |