Airflow Meter & Sensor Check

Turn ignition off. Unplug wiring connector from airflow meter. Note terminal identification. Using an ohmmeter, measure resistance between specified terminals. On Supra Turbo models, use only an analog ohmmeter. Replace airflow meter if not within specification. See AIRFLOW METER RESISTANCE SPECIFICATIONS  table.

Fig 1: View of Airflow Meter
G118889Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Fig 2: Airflow Meter Terminal Identification
G118890Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
AIRFLOW METER RESISTANCE SPECIFICATIONS

Terminals Ohms
E2-Vc 200-400
E1-Fc
Measuring Plate Fully Closed Infinity
Measuring Fully Plate Open 0
E2-Vs
Measuring Plate Fully Closed 200-600
Measuring Plate Fully Open 20-1200
E2-THA
-4°F (20°C) 10,000-20,000
32°F (0°C) 4000-7000
68°F (20°C) 2000-3000
104°F (40°C) 900-1300
140°F (60°C) 400-700
NOTE: Air temperature sensor is tested as part of airflow meter.